EMAIL: PASSWORD:
Front Office
UPT. PERPUSTAKAAN
Universitas Esa Unggul


Kampus Emas UEU - Jakarta Barat

Phone : 021-5674223, ext 282
Fax :
E-mail : [email protected]
Website : http://library.esaunggul.ac.id

Support (Customer Service) :
[email protected]








Welcome..guys!

Have a problem with your access?
Please, contact our technical support below:
LIVE SUPPORT


Astrid Chrisafi




! ATTENTION !

To facilitate the activation process, please fill out the member application form correctly and completely
Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently

Still Confuse?
Please read our User Guide

Keyword
Mode
Expanded Search (for Free text search only)
 

UEU » Master Theses » Magister Manajemen
Posted by [email protected] at 16/12/2014 12:31:46  •  2007 Views


EVALUATION OF ELECTROMYOGRAPHY IN PATIENTS WITH LONG-TERM LOW-BACK PAIN AND IN HEALTHY SUBJECTS

Created by :
Britt Elfving ( 54 )



SubjectEvaluation of electromyography in patients with long-term low-back pain and in healthy subjects
Alt. Subject Evaluation of electromyography in patients with long-term low-back pain and in healthy subjects
KeywordDisability
electromyography
exponential
force level
gender
healthy subjects
interelectrode distance
low-back pain
erector spinae
maximal voluntary contraction
muscle fatigue
recovery
reliability
validity.

Description:

Lumbar muscle function is considered to be an important component of longterm low-back pain. The change in the median frequency of the power spectrum of the electromyographic (EMG) signal is commonly used to estimate muscle fatigue. Aim: The main purpose was to evaluate a test method to estimate lumbar muscle fatigue using frequency analysis of the electromyographic signal during isometric contraction. Methods: In the different studies, 73 healthy subjects participated; 55 of these constituted a reference group which was compared to 57 patients with long-term low-back pain. The subjects performed a back extensor test in seated position: maximal voluntary contraction (MVC) torque, 45 s isometric fatigue contraction at 80% of MVC, 5 s contractions after 1, 2, 3 and 5 min in the recovery period. Surface EMG was recorded from the lumbar muscles bilaterally at spinal levels L1 and L5. To study reliability, this test was repeated five times by 11 of the healthy subjects and once by 20 of the patients. In a further study, 15 of the healthy subjects performed the fatigue test at 40% and 80% of MVC with both 2 cm and 4 cm interelectrode distances. EMG variables were initial median frequency, median frequency slope (obtained from linear regression of the fatigue contraction) and recovery half-time (obtained from non-linear regression of the recovery data). Activity, participation and other health-related factors were estimated by the patients in five questionnaires. Results: The reliability was somewhat higher for patients (ICC>0.6) than for healthy subjects. The initial median frequency and, to a greater extent, the slope were sensitive to the exerted torque. The patients differed from the healthy subjects by lower MVC torque, higher initial median frequency at L5, and by flatter slope and longer recovery half-time at both lumbar levels. Using logistic regression entering EMG initial median frequency, slope and recovery half-time in combination with MVC, about 80% of the patients and the healthy subjects could be correctly classified. By analyses of individual linear and non-linear regressions, it was found that patients with not significantly negative slopes and/or not exponential-like EMG recovery had lower self-efficacy and more activity limitations. Female patients had significantly flatter slopes, lower physical functioning and self-efficacy than male patients. The results indicate that the ability to fatigue the lumbar muscles in a 80% MVC contraction might be a healthy sign

Date Create:16/12/2014
Type:Text
Format:pdf
Language:Indonesian
Identifier:UEU-Master-undergraduate_54
Collection ID:undergraduate_54
Call Number:658.1 BEe


Source :
magister these management of faculty

Relation Collection:
Universitas Esa Unggul

Coverage :
Civitas Akademika Universitas Esa Unggul

Rights :
copyright2014_Library@esaunggul


Publication URL :
https://digilib.esaunggul.ac.id/evaluation-of-electromyographyin-patients-with-longterm-lowback-painand-in-healthy-subjects-4260.html




[ Free Download - Free for All ]

  1.  UEU-Master-4260-ABSTRAK1_ET00000024_Britt.pdf - 13 KB
  2.  UEU-Master-4260-COVER1_ET00000024_Britt.pdf - 30 KB
  3.  UEU-Master-4260-DAFTAR ISI1_ET00000024_Britt.pdf - 12 KB
  4.  UEU-Master-4260-DAFTAR PUSTAKA1_ET00000024_Britt.pdf - 59 KB
  5.  UEU-Master-4260-SINGKATAN1_ET00000024_Britt.pdf - 8 KB

[ FullText Content - Please, register first ]

  1. UEU-Master-4260-BAB 11_ET00000024_Britt.pdf - 10 KB
  2. UEU-Master-4260-BAB 21_ET00000024_Britt.pdf - 54 KB
  3. UEU-Master-4260-BAB 31_ET00000024_Britt.pdf - 7 KB
  4. UEU-Master-4260-BAB 41_ET00000024_Britt.pdf - 70 KB
  5. UEU-Master-4260-BAB 51_ET00000024_Britt.pdf - 49 KB
  6. UEU-Master-4260-BAB 61_ET00000024_Britt.pdf - 52 KB
  7. UEU-Master-4260-BAB 71_ET00000024_Britt.pdf - 19 KB
  8. UEU-Master-4260-BAB 81_ET00000024_Britt (2).pdf - 11 KB

 10 Similar Document...

     No similar subject found !

 10 Related Document...






HELP US !
You can help us to define the exact keyword for this document by clicking the link below :

Disability , contraction , distance , electromyography , erector , erector spinae , exponential , force , force level , gender , healthy , healthy subjects , interelectrode , interelectrode distance , level , low-back , low-back pain , maximal , maximal voluntary contraction , muscle fatigue , pain , recovery , reliability , spinae , subjects , validity. , voluntary



POLLING

Bagaimana pendapat Anda tentang repository kami ?

Bagus Sekali
Baik
Biasa
Jelek
Mengecewakan




157320984


Visitors Today : 3
Total Visitor : 1970111

Hits Today : 72527
Total Hits : 157320984

Visitors Online: 1


Calculated since
16 May 2012

You are connected from 172.17.121.29
using Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; [email protected])


UEU Digital Repository Feeds


Copyright © UEU Library 2012 - 2024 - All rights reserved.
Dublin Core Metadata Initiative and OpenArchives Compatible
Developed by Hassan